maximum width: 1,8 m
Diameter (mm) | 2 | 2,5 | 3 | 4 | 6 | 8 | |
---|---|---|---|---|---|---|---|
Mesh size | |||||||
50 x 50 mm | X | X | X | X |
|
| |
50 x 100 mm | X | X | X | X | X | X | |
100 x 100 mm |
|
| X | X | X |
| |
100 x 150 mm |
|
| X | X | X | X | |
100 x 200 mm |
|
|
| X | X | X | |
150 x 150 mm |
|
|
| X | X | X | |
200 x 200 mm |
|
|
| X | X | X |

The composite solution for reinforcement.
Structural elements often need to be restored or even replaced due to corrosion damage to the steel reinforcement, which leads to destruction of the concrete structure. This applies in particular to components that are exposed to road salt. With the use of GRP reinforcement, corrosion is a thing of the past. It drastically reduces the number of component repairs needed. GFRP reinforcements are mainly used for concrete and polymer concrete components.
maximum width: 1,8 m
Diameter (mm) | 2 | 2,5 | 3 | 4 | 6 | 8 | |
---|---|---|---|---|---|---|---|
Mesh size | |||||||
50 x 50 mm | X | X | X | X |
|
| |
50 x 100 mm | X | X | X | X | X | X | |
100 x 100 mm |
|
| X | X | X |
| |
100 x 150 mm |
|
| X | X | X | X | |
100 x 200 mm |
|
|
| X | X | X | |
150 x 150 mm |
|
|
| X | X | X | |
200 x 200 mm |
|
|
| X | X | X |
E-Modulus GPa 40
Tensile strength MPa 200
Sizes | Rods/m | Minimum tensile strength Mesh - N/m | |||||
---|---|---|---|---|---|---|---|
Rod Diameter mm | 2 | 2,5 | 3 | 4 | 6 | 8 | |
50 x 50 mm | 212.560 | 19.625 | 28.260 | 50.240 | 113.040 | 200.960 | |
50 x 100 mm | 10 | 6.280 | 9.813 | 14.130 | 25.120 | 56.520 | 100.480 |
100 x 100 | 10 | 6.280 | 9.813 | 14.130 | 25.120 | 56.520 | 100.480 |
100 x 150 mm | 7 | 4.396 | 6.869 | 9.891 | 17.584 | 39.564 | 70.336 |
100 x 200 mm | 5 | 3.140 | 4.906 | 7.065 | 12.560 | 28.260 | 50.240 |
150 x 150 mm | 7 | 4.396 | 6.869 | 9.891 | 17.584 | 39.564 | 70.336 |
200 x 200 mm | 5 | 3.140 | 4.906 | 7.065 | 12.560 | 28.260 | 50.240 |
Charakteristics | Steel Reinforcement | GRP-Reinforcement |
---|---|---|
Material | Steel | GRP |
Tensile strength, MPa | 360-390 | 1200-1300 |
E-Modul, MPa | 200000 | 60000 |
Elongation at break, % | 25 | 2,2 |
Lin. Thermal expansion coefficient, 10-6/K | 13-15 | 9-12 |
Density, kg/dm3 | 7 | 1,9 |
Length | 6-12m | 6m or as required |
Corrosion and chemical resistance | no | yes |
Thermal conductivity | yes | no |
Dielectric | no | yes |
Radiolucent | no | yes |
Insensitivity to electromagnetic fields | no | yes |
Expected service life | 30 Years | 100 Years |
Diameter Ø | 4, 6, 8, 10, 12, 14 mm |