GRP profile type MR Mats/roving-reinforced | GRP profile type UD Roving reinforced | ||
---|---|---|---|
Z | X | Z | |
Tensile strength | 250–450 MPa | 20–60 MPa | 900 MPa |
Bending strength | 250–450 MPa | 20–60 MPa | 900 MPa |
Elastic modulus (tensile strength) | 25,000 MPa | 9,000 MPa | 40,000 MPa |
Elastic modulus (bending) | 25,000 MPa | 9,000 MPa | 40,000 MPa |
Elongation at break | 1.0–1.8% | 2% | |
Compression resistance | 150–300 MPa | 30–60 MPa | 450 MPa |
Pressure module | 10,000 MPa | 4,000 MPa | 30,000 MPa MPa |
Density | 2.0 kg/dm³ | 2.1 kg/dm³ | |
IZOD impact strength test | 90–120 kJ/m² | 120 kJ/m² | |
Barcol hardness | > 40 | > 50 |
Characteristic values
Depending on the type of fiber reinforcement of the profile structure and the wall thickness, the technical data of the GRP profiles vary. The application-specific suitability must be checked in each individual case.
Interlaminar shear strength | 25 - 35 MPa |
Specific volume resistivity | 10^10 - 10^15 Ohm * cm |
Surface resistance | 10^10 - 10^15 Ohm |
Dielectric strength | 5 - 10 kV/mm |
Tracking resistance CTI | KA 3c / KB 500 / KC 600 |
Dielectric constant | < 5 |
Lin. Coefficient of thermal expansion | 12 x 10 -61/K |
Thermal conductivity | 0,2 - 0,6 W/m*K |
Spec. heat capacity | 1,0 - 1,2 kJ/kg*K |
Continuous operating temperature | -100°C to +155°C (180°C) |
Water absorption | < 0,15% |
Dimensional stability n. Martens | 200°C |
Ember resistance | Level 2b |
Fire behaviour | B2, UL94 V1, UL94 V0, DIN 5510 S4 SR2 ST2, ASTM E84 < 25, ASTM D635 |
Short-term behaviour | Long-term behaviour | |||
---|---|---|---|---|
Type MR | Z | X | Z | X |
Bending stress | 135 MPa | 20 MPa | 70 MPa | 15 MPa |
Tensile stress | 135 MPa | 20 MPa | 70 MPa | 15 MPa |
Compressive stress | 135 MPa | 25 MPa | 70 MPa | 20 MPa |
Shear stress Z=X | 25.000 MPa | 8 MPa |