The tests were carried out with GFRP profiles. The flammability must be coordinated with the respective application.

StandardTest method/comment CountryResult
ÖNORM B 3800B1-Test/
/phenolic resin
AB1 Tr1 Q1
UNIFER E 10.02.977UNI 9177
Classification
CH, I2A
UNIFER E 10.02.977UNI 9174
Fire temperature FT
CH, I2A
UNIFER E 10.02.977UNI 8457 KI FTCH, I2A
UNIFER E 10.02.977ISO 5660-1
Heating energy
CH, Isee test result
UNIFER E 10.02.977EN ISO 1716
Heating value
CH, I7639 J/g
DIN 53 438, part 25 mmDK 1/5 mm
DIN 54837DIN 55 10 T2DS4 SR2 ST2
DIN EN 13501 –1DIN EN
ISO 9239 -1
D EU9,9 kW/m2 /
195% min
DIN EN 13501 –1DIN EN
ISO 11925-2
D EUStandards fulfilled
DIN EN 13501 –1(≈DIN 4102-B1)D EUBfl –s1
NFF16 -101NF X 70 -100
Toxicity
FF1/I.T.C.-value: 2,3
NFF16 -101NF X 10 -702
Smoke
FF1/I.T.C.-value: 2,3
NFF16 -101NF P 92-501 fireFM 2
BS 476: Part 7: 19978 mmGBClass 2
BS 476: Part 7: 19973 mmGBClass 2
UIC 564-2: 1994Annex 4Hfire C / smoke A
NFPA 130ASTM E 662
Smoke density
USAsee test result
NFPA 130ASTM E 162
Flame spread
USAIs = 9,7
NFPA 255ASTM E-84-98USA< 25, class A
Code 95/28/EG: 1995Automobile Code,
rate of fire 
95/28/EG: 1995
EUStandards fulfilled
EN ISO 11925-2: 2002CEN/TS
45545-2: 2009
Ignition
EUStandards complied
ISO 5660-1: 2002CEN/TS
45545-2: 2009
Heat release
EUMAHRE 50,7 kW/m2
ISO 5658-2: 2006CEN/TS
45545-2: 2009
Flame propagation
EUCFE > 20 kW/m2
Qsb 8,13 MJ/m2
ISO 5659-2: 2007CEN/TS
45545-2: 2009
Toxicity of fire gases
EUDs (4) 89
VOF 4 95
CIT 4 min 0,01
CIT 8 min 0,02
ISO 4589-2Oxygen index
by RT
EULOI 36,2%
DIN EN 60695-11-10Vertical test
UL94 V
EU V 0
EN 45545EN 45545-2:2013EUHL 1-3
EN ISO 5659-2:2012EN 45545-2:2013EU25bW/m², Ds max 109
NF X 70-100-1:2006EN 45545-2:2013EUT12, CITNLP 0,03
DIN EN ISO 4589-2:2006EN 45545-2:2013EULOI 36%
DIN EN 13823:2010DIN EN 13501-1:2010EUB, s1, d0