Technical Data   Mesh Grids

Dimensions available

max. Hight: 1,8 m

 

Diameter

2 mm
2.5 mm
3 mm
4 mm
6 mm
8 mm

Mesh Size

             
50 x 50 mm
 
           X
               X
           X
           X
          
 
50 x 100 mm
 
      X
         X
      X
      X
      X
 
100 x 100 mm
     
           X
           X
           X
 
100 x 150 mm
     
      X
      X
      X
      X
100 x 200 mm
       
           X
           X
           X
150 x 150 mm
       
      X
      X
      X
200 x 200 mm
       
      X
      X
      X

Comparison of Steel- and GRP Reinforcements

Characteristics Steel Reinforcement GRP Reinforcement
Material Steel GRP
Tensile strenght, Mpa 360-390 1200-1300
E-Module, Mpa 200000 60000
Elongation at fracture, % 25 2,2
Lin. expansion-
coefficient, 10-6/K
13-15 9-12
Density, kg/dm³ 7 1,9
Length 6-12 m 6 m or at request
Corrosion- and
chemical resistance
no yes
Thermal conductivity yes no
Dielectric no yes
Radiotranslucent no yes
Insensitive to 
electromagnetic fields
no yes
life expectancy 30 years 100 years

Advantages over Steel

  • resistant to corrosion and acids
  • extended service life
  • no maintenance required
  • lightweight with high tensile strenght
  • permeable to magnetic fields and radio frequencies