Path:  Main  »  GRP Profiles  »  Tolerances
   
 
Dimensional Tolerances for GRP Profiles
PropertyTolerance
Profile height and width of flange

Nominal dimensions (mm)
- B and H: ±  0,5 %
  with minimum ± 0,20 mm
- B and H: ±  0,5 %
  with maximum ± 0,75 mm

Diametre of Rods and Tubes

D, d (mm)ΔDΔd
0 - 10
10 - 20
20 - 50
50 - 100
100 -
± 0,20
± 0,30
± 0,35
± 0,40
± 0,45
± 0,20
± 0,30
± 0,35
± 0,40
± 0,45
Wall-thickness of open
and closed profiles

Nominal dimensions (mm)
ThicknessT1T2
0 - 2
2 - 5
5 - 10
10 -
± 0,15
± 0,20
± 0,35
± 0,45
± 0,30
± 0,35
± 0,45
± 0,50
Flatness in transverse direction
Tolerance
F < 0,008 X B mm
Size of angle
Tolerance
Y ± 1,5°
Straightness
Tolerance (B and H are overall
breadth and height dimensions)
- D < 0,002 x L2 for sections
  with B or H < 50 mm
- D < 0,001 x L2 for sections
  with B or H ≥ 50 mm and < 100 mm
- D < 0,0005 x L2 for sections
  with B or H ≥ 100 mm
Twist
Tolerance
- V < 1,5° per metre maximum
  for thickness < 5 mm
- V < 1,0° per metre maximum
  for thickness ≥ 5 mm
Length of cut
L + 20 / - 0 mm
Angularity of cut
V ± 1,5°